This page describes NCC 2022 provisions as published by the Australian Building Codes Board. NCC 2025 is the later edition and is not compared here. It is not building or fire-safety advice, and no design is assessed.
Mass timber at a glance
What it isLarge solid timber elements such as cross-laminated timber (CLT) panels, whose fire behaviour relies partly on a char layer[1]
Fire-protected timber height limitEffective height not more than 25 m under NCC 2022 clause C2D13[2]
SprinklersRequired for buildings using that concession, to Specification 17, with named exceptions[2]
Exposed timberTreated by AFAC as a performance-based approach rather than deemed-to-satisfy[1]
PricesNot covered by sources compiled here

Cross-laminated timber (CLT) is the best-known form of mass timber: large solid timber panels used as walls, floors and roofs. Panels are made off site, which is why they appear in prefab and modular building. The rules that matter most are fire rules, and they depend on the NCC class and height of the building. This page sets out what the Australian Building Codes Board's published provisions and a fire-services guideline say. For where CLT sits among other framing materials, see timber framing and engineered wood and what prefab homes are built from.

What counts as mass timber §

The Australasian Fire and Emergency Service Authorities Council (AFAC) uses "massive timber" for panels such as CLT, and notes that these resist fire partly because a char layer forms and insulates the unburnt wood beneath.[1] Detail on the manufacturers that supply CLT in Australia is in material suppliers. How an exposed CLT surface behaves as an interior finish is in interior finishes in modular homes.

Where the fire rules apply §

BuildingCode volumeMass timber rule source
Class 1 houseVolume Two[3]Not covered by sources compiled here
Class 2 or 3 low-riseVolume OneTimber concession[3]
Class 2 or 3 tallerVolume OneFire-protected timber[2]

The Board's advisory note confirms that Class 1 and Class 10 buildings fall under Volume Two, not the Volume One provisions it discusses.[3] For how classes are decided, see building classes for shared housing. The sources compiled here do not set out what Volume Two requires of a CLT house, so this page does not state it.

Low-rise Class 2 and 3 concessions §

For Class 2 and 3 buildings, Volume One contains concessions that let timber framing be used where non-combustible construction would otherwise be required. They apply to Type A buildings of not more than three storeys rise and Type B buildings of not more than two.[3] Cladding, spandrel coverings and some linings must still be non-combustible, and bushfire-prone area requirements still apply.[3] Multi-unit modular forms are discussed in modular apartments (Class 2).

Fire-protected timber up to 25 m §

NCC 2022 clause C2D13 lets fire-protected timber be used where an element would otherwise need to be non-combustible. The conditions are that the building or relevant part is separated from the rest of the building, the effective height is not more than 25 m, the building is sprinkler protected to Specification 17 (with exceptions for two named systems), insulation inside the system is non-combustible, and cavity barriers are provided.[2] A fire wall or floor that must have a fire-resistance level cannot itself be fire-protected timber.[2]

Specification 10 describes the protection. A general route uses a non-combustible covering that resists incipient spread of fire for at least 45 minutes, or two layers of 13 mm fire-protective grade plasterboard. A separate route for massive timber sets covering performance by application, using a 300 degrees Celsius limit at the timber interface for 20, 30 or 45 minutes, or minimum plasterboard thicknesses of 13 mm, 16 mm or 2 x 13 mm. Cavities must be filled with non-combustible insulation or be absent, and test evidence must come from an accredited laboratory.[4]

According to Forest and Wood Products Australia, an industry body, the 25 m limit was introduced for all classes in NCC 2019, having previously covered Classes 2, 3 and 5 only.[5] That is commentary on a superseded edition; the current wording is in the NCC.

Exposed timber §

AFAC describes covering timber with a non-combustible layer as the deemed-to-satisfy approach, and leaving it exposed as a performance-based approach that relies on char behaviour and needs analysis.[1] It lists concerns for exposed timber: extra fuel, glue delamination, weak connections, external fire spread and difficulty for firefighters.[1] Where combustible materials are restricted, such as Type A or B construction, it says a performance solution would generally be needed.[1] The guideline states it is not prescriptive and does not guarantee compliance.[1]

What is not covered here §

Fire and building-surveyor decisions are made per project by the certifier. Nothing here is compliance advice.

Ask Modular Living AI about this guide

Still have a question after reading this guide? Ask it here. The answer draws on this guide, our other guides and the official pages they cite, with links to each one it used.

General information only, not legal, financial or building advice.

The Dispatch — a monthly email when new guides are published. No noise; unsubscribe anytime.

Sent to info@modularlivingaustralia.com.au and handled by a person. See Privacy.

References §

  1. Australasian Fire and Emergency Service Authorities Council — Fire Safety Principles for Massive Timber Building Systems, version 1.0 (30 April 2018) — Guideline stating that massive timber such as CLT resists fire partly through a char layer insulating unburnt wood. Describes encapsulation (fire-protected timber) as the deemed-to-satisfy approach and exposed timber as a performance-based approach needing analysis. Raises concerns for exposed timber: added fuel, delamination of adhesive, weak connections, external fire spread and firefighting difficulty. Says buildings with restrictions on combustible materials, such as Type A or B construction, would generally need a performance solution if timber is exposed. States it is not prescriptive and does not guarantee compliance. esa.act.gov.au/sites/default/files/2019-06/massive-timber-buildings.pdf
  2. Australian Building Codes Board — NCC 2022 Volume One, Part C2 Fire resistance and stability — C2D13 allows fire-protected timber where an element must otherwise be non-combustible. Conditions: the building or relevant part is separated from the rest of the building (fire walls and floors that need a fire-resistance level cannot be fire-protected timber); effective height not more than 25 m; sprinkler protection to Specification 17 (except under an FPAA 101D or 101H system) in addition to E1D4; non-combustible insulation within the system; cavity barriers to Specification 9. abcb.gov.au/editions/ncc-2022/adopted/volume-one/c-fire-resistance/part-c2-fire-resistance-and-stability
  3. Australian Building Codes Board — Advisory Note 2020.1, Class 2 and 3 buildings: concessions for use of timber framing and/or non-combustible materials (August 2020) — Explains NCC Volume One concessions letting certain low-rise Class 2 and 3 buildings use timber framing where non-combustible construction would otherwise be required: Type A buildings of not more than three storeys rise and Type B of not more than two. Class 1 and 10 buildings fall under Volume Two and are outside the note. Cladding and some linings must remain non-combustible, and bushfire-prone area requirements still apply. nccb.gov.au/sites/default/files/resources/2022/Advisory-Note-timber-framing-concessions.pdf
  4. Australian Building Codes Board — NCC 2022 Volume One, Specification 10 Fire-protected timber — Sets out protection of timber elements by non-combustible coverings. General protection (S10C2): the covering must allow the element to reach its required fire-resistance level and resist incipient spread of fire for at least 45 minutes, or use two layers of 13 mm fire-protective grade plasterboard. Massive timber alternative (S10C3): a table of covering performance, with a 300 degrees Celsius limit at the timber interface for 20, 30 or 45 minutes depending on the application, or minimum plasterboard thicknesses of 13 mm, 16 mm or 2 x 13 mm. Cavities must be filled with non-combustible insulation or be absent. Test results must come from an accredited testing laboratory. ncc.abcb.gov.au/editions/ncc-2022/adopted/volume-one/c-fire-resistance/10-fire-protected-timber
  5. Forest and Wood Products Australia — NCC changes mean the sky is almost the limit for timber construction (28 February 2019) — Industry body article on NCC 2019. States that fire-protected timber systems could be used up to 25 m effective height, typically eight storeys, extended from Classes 2, 3 and 5 to all building classes, and that sprinklers are compulsory in Class 2 and 3 buildings of four to eight storeys. Industry commentary on a superseded edition. fwpa.com.au/news/ncc-changes-mean-the-sky-is-almost-the-limit-for-timber-construction

Figures are as published by the sources above at their respective dates and are paraphrased summaries, not verbatim reproductions. Verify current pricing and rules directly with builders, lenders and planning authorities.