Timber vs steel framing for prefab homes

This page compares framing materials as the National Construction Code (NCC) 2022 and related government sources describe them; it is not building advice and assesses no product or builder. The NCC is adopted with variations by each state and territory, and a provision that is published is not necessarily in force on a given site or date. Which edition and variations apply to a project is a matter for the certifier.
Timber and steel at a glance
Where the NCC addresses framingSteel framing at H1D6(3) and timber framing at H1D6(4) of Volume Two[1]
TermitesPart 3.4 treats elements made wholly of steel as not susceptible; treated or naturally resistant timber is also treated as not susceptible[2]
Thermal bridgingNatHERS applies thermal bridging only to steel framing, so timber ratings are unchanged[3]
BushfireAS 3959 and the NASH bushfire standard are both deemed-to-satisfy solutions[4][5]
Delivered costNot covered by sources compiled here
*Provisions are as published for NCC 2022 and may differ by state or territory variation.

Timber and steel are the two frame materials used in most factory-built Australian homes, and the National Construction Code treats them through separate provisions rather than a single comparison.[1] This page sets the two side by side on the points where official sources distinguish them: framing provisions, termites, bushfire and thermal bridging. Each material has its own guide, linked below, which holds the detail.

How the code treats each material §

Volume Two of the NCC deals with steel framing at clause H1D6(3) and timber framing at H1D6(4), with a structural-software provision at H1D6(7).[1] For steel and timber framing the code points onward to Part 6.3 of the ABCB Housing Provisions.[6] Subfloor ventilation rules in Part 6.2 apply to the space under any suspended floor, whether it is timber, steel-framed or concrete.[1]

The provision on software states it does not apply to tools that only automate manual methods, and names AS 1684 span tables and bracing calculations as an example of that kind of method.[6] The standards that sit behind each material are described in timber framing and engineered wood and steel framing in prefab homes; the wider list is in Australian standards for prefab buildings.

Side-by-side on the points sources address §

TopicTimberSteel
NCC framing clauseH1D6(4)[1]H1D6(3)[1]
Termite provisionsTreated or resistant timber not susceptible[2]Wholly steel elements not susceptible[2]
NatHERS thermal bridgingNot applied[3]Applied to studs and joists[3]
Wall thermal breakNot covered by sources compiled hereR0.2 in defined Class 2 and 4 cases[7]
Bushfire standardsAS 3959[5]AS 3959 or NASH[4]
Delivered costNot covered by sources compiled hereNot covered by sources compiled here

Termites §

Part 3.4 of the Housing Provisions applies to Class 1 and Class 10 buildings in areas where subterranean termites are a known risk and where a primary building element is susceptible to attack. It works element by element rather than by frame type: elements made wholly or partly of steel or other metals, concrete, masonry or fibre-reinforced cement are treated as not susceptible, as is timber that is suitably treated or naturally resistant.[2] A frame is therefore only one of the primary elements the provision looks at.

Treated and naturally resistant timber are defined by reference to AS 3660.1, as are termite management systems themselves.[2] The Northern Territory and Queensland vary these rules, and the explanatory material describes termites as not considered a risk in Tasmania and a lesser risk in parts of Victoria.[2] How the variations in other states apply is not covered by sources compiled here. Detail on treatment classes is in timber framing and engineered wood, and termite measures at the footing are touched on in modular home foundations.

Bushfire §

Two routes are recognised for homes in bushfire-prone areas. AS 3959 assigns a Bushfire Attack Level from BAL Low (no bushfire requirements) through BAL 12.5, 19, 29 and 40 to Flame Zone, with exposure rising from embers to radiant heat to direct flame.[5] The NCC references it as a deemed-to-satisfy solution, and its stated aim is to protect occupants until the fire front passes and give the building some protection, not to guarantee survival in every fire.[5]

The NASH bushfire standard is the second deemed-to-satisfy route. According to the Victorian Government's Emergency Recovery Victoria factsheet, NASH relies on non-combustible materials throughout, uses AS 3959 to establish the BAL, and offers its own solutions for BAL 12.5 to 40 and Flame Zone. The factsheet contrasts this with AS 3959 construction, which it says depends more on the outer cladding remaining sealed.[4] The factsheet compares the two standards; it does not compare timber and steel frames directly, and no source compiled here does.[4] The requirements at each BAL level are not covered by sources compiled here; see steel framing in prefab homes for the NASH standard.

Thermal performance §

Under NCC 2022 the NatHERS rating tool applies thermal bridging only to repeating steel elements such as studs and joists in floors, walls and ceilings; timber-framed homes are unaffected and their ratings stay the same. The stated aim is to rate steel-framed homes as though they performed like timber-framed ones, not to model their actual performance, and designers can offset the difference elsewhere in the home.[3] The result is a modelling rule, not a measurement of how either frame performs in use.

Separately, NCC 2022 Volume One requires a thermal break of at least R0.2 in certain metal-framed walls of Class 2 and Class 4 part units, where external cladding touches the metal frame and the wall is unlined or lined directly to the frame; insulated sandwich panels are exempt.[7] The equivalent rule for Class 1 houses is not covered by sources compiled here, because the Housing Provisions text retrieved was a state variation and has not been extended to other states. Panel systems that avoid frames altogether are covered in structural insulated panels (SIPs).

Cost, weight and lead time §

Published cost comparisons between timber and steel frames, and their effect on transport or crane weight, are not covered by sources compiled here. For cost structure in general see prefab home costs and modular home cost breakdown. Any builder-quoted price difference is builder-published commercial guidance, not independent survey data.

What is not covered here §

This page does not establish market share by material today, or how often either frame type is chosen for Class 1 modular homes. It does not cover cost, weight, fire resistance ratings for Class 2 to 9 buildings, acoustic performance, moisture and corrosion behaviour, or embodied carbon.

It relies on NCC 2022 provisions as published by the ABCB and does not check NCC 2025 or any state or territory variation beyond those the cited pages mention. It does not cover the content of AS 1684, the NASH standards or AS/NZS 4600 themselves, which are held by their publishers. Several publisher pages could not be retrieved while compiling it, so claims depending on them are left to the linked material guides.

Nothing here is a design, compliance or purchasing recommendation.

Ask Modular Living AI about this guide

Still have a question after reading this guide? Ask it here. The answer draws on this guide, our other guides and the official pages they cite, with links to each one it used.

General information only, not legal, financial or building advice.

The Dispatch — a monthly email when new guides are published. No noise; unsubscribe anytime.

Sent to info@modularlivingaustralia.com.au and handled by a person. See Privacy.

References §

  1. Australian Building Codes Board — ABCB Housing Provisions, Part 6.1 (Section 6 framing) — Scope page for Section 6. States that Section 6 covers subfloor ventilation (Part 6.2) and structural steel members (Part 6.3); that other framing is governed by NCC Volume Two, with steel framing at H1D6(3), timber framing at H1D6(4) and structural software at H1D6(7); that Part 6.2 applies to the subfloor space of all suspended floors, whether timber, steel-framed or concrete; and that Section 6 is subject to state and territory variations. cpd.nccb.gov.au/editions/ncc-2022/adopted/housing-provisions/6-framing/part-61-scope-and-application-section-6
  2. Australian Building Codes Board — ABCB Housing Provisions, Part 3.4 Termite risk management — States that Part 3.4 applies to Class 1 and Class 10 buildings in areas where subterranean termites are a known risk and where a primary building element is susceptible to attack. Elements made wholly or partly of steel, aluminium or other metals, concrete, masonry, fibre-reinforced cement, or suitably treated or naturally resistant timber are treated as not susceptible. AS 3660.1 is referenced for naturally resistant and preservative-treated timber (Appendices C and D) and for termite management systems. Northern Territory and Queensland carry variations; the explanatory material says termites are not considered a risk in Tasmania and are a lesser risk in parts of Victoria. cpd.nccb.gov.au/editions/ncc-2022/adopted/housing-provisions/3-site-preparation/part-34-termite-risk-management
  3. Nationwide House Energy Rating Scheme (NatHERS) — Thermal bridging, NCC 2022 — States that under NCC 2022 timber-framed homes are not affected by thermal bridging calculations and their ratings stay the same; steel framing is penalised only in repeating elements such as studs and joists in floors, walls and ceilings; default values apply where framing details are unavailable; the aim is to rate steel-framed homes as if they performed like timber-framed ones rather than to model actual performance; and designers can offset the difference elsewhere in the home. nathers.gov.au/node/515
  4. Emergency Recovery Victoria — Steel framing standards factsheet (Victorian Government) — States that the NASH steel framing bushfire standard and AS 3959 are both deemed-to-satisfy solutions under the NCC for homes and low-rise buildings in bushfire-prone areas; AS 3959 sets the Bushfire Attack Level (BAL) from BAL 12.5 to Flame Zone; NASH uses non-combustible materials throughout and uses AS 3959 to determine the BAL; and the factsheet contrasts NASH's non-combustible approach with AS 3959 construction relying more on the outer cladding staying sealed. It does not directly compare timber framing with steel. vic.gov.au/sites/default/files/2023-08/ERV-Steel-Framing-Standards-Factsheet.pdf
  5. Housing Industry Association — Construction of buildings in bushfire-prone areas (AS 3959 overview) — Describes the BAL categories from BAL Low (no bushfire requirements) through BAL 12.5, 19, 29, 40 and Flame Zone, with increasing exposure to embers, radiant heat and direct flame. States that the standard aims to protect occupants until the fire front passes and some protection for the building, not survival in every fire, and that the NCC references it as a deemed-to-satisfy solution. The page does not address steel framing. hia.com.au/resources-and-advice/building-it-right/australian-standards/articles/construction-of-buildings-in-bushfire-prone-areas
  6. Australian Building Codes Board — NCC 2022 Volume Two, Part H1 Structure — States that H1D6 points to Part 6.3 of the Housing Provisions for steel and timber framing, that H1D6(7) on structural software does not apply to software that merely automates manual methods such as AS 1684 span tables and bracing calculations, and that insulation weight should be considered when selecting plasterboard, fixings and framing. abcb.gov.au/editions/ncc-2022/adopted/volume-two/h-class-1-and-10-buildings/part-h1-structure
  7. Australian Building Codes Board — NCC 2022 Volume One, J3D6 wall thermal breaks (Class 2 and Class 4 part) — States that metal-framed walls forming part of the envelope of a sole-occupancy unit in a Class 2 building, or a Class 4 part of a building, need thermal breaks where the wall is unlined or lined directly to the frame and clad in weatherboard, fibre-cement or metal sheeting; the break must be at least R0.2 wherever external cladding contacts the metal frame; insulated sandwich panels are exempt. abcb.gov.au/guide/j3d6-wall-thermal-breaks-sole-occupancy-unit-class-2-building-or-class-4-part-building

Figures are as published by the sources above at their respective dates and are paraphrased summaries, not verbatim reproductions. Verify current pricing and rules directly with builders, lenders and planning authorities.